Philips INCA 320 User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
The inputs and outputs are not protected in any way, so
care must be taken when connecting anything to these
inputs and/or outputs.
All inputs and outputs are TTL level compatible.
output current 0.9 mA < Ion < 18 mA, Vce max 40 volt
Pmax 20 mW
2.3.3 Digital I/O
The Digital Input and Output connectors give the user
the possibility to connect and control a number of devices.
For that purpose 6 output and 6 input lines are available.
These output and input lines are optically isolated from the
Inca.
Input 6 differs from the other inputs in a way that it has a
special purpose. Input 6 can also be used as an interrupt
input that is either level or edge sensitive.
Page 8 2005-12-12
Figure 2-6: Digital input and output connections
Table 2-1: LED control by Rhapsody software
LED 1 green or yellow
LED 2 green or yellow
LED 3 green or yellow
LED 4 green (only!)
DIGITAL I/O
PIN
INPUT
Input 4
Input 1
Input 2
Input 6
Input 3
Ground 6
Input 5
8
7
6
5
4
3
2
1
Common Ground 1..5
PIN
OUTPUT
Output 4
Common 24V 4..6
Output 6
Output 2
Output 5
Output 1
Common 24V 1..3
8
7
6
5
4
3
2
1
Output 3
Note: The common 24V lines of the outputs are clustered
in two groups of three outputs. Five input common grounds
are also clustered.
2.3.3.1 Digital Inputs
The following diagram shows one input.
1
Common
Ground
Signal In
15V
940
In
p
ut
Out
p
ut
1
Figure 2-7: Digital Input