8-3 PL12.2ATR
[Video Signal Section]
No
Is the "L" pulse sent ou
t Pin(1) terminal of remote
control receiver (RS4051) when the
infrared remote
control is activated?
Ye s
Is the "L" pulse supplied to Pin(5) of CN4001?
Ye s
Is approximately +3.3V voltage supplied to Pin(3)
terminal of the remote co
ntrol receiver (RS4051)?
No
FLOW CHART NO.2
Check AL+3.3V line and service it if defective.
No
Replace the remote control receiver (RS4051)
or the remote control unit.
Check the line between Pin(1) of remote control
receiver (RS4051) and Pin(5) of CN4001, and
service it if defective.
Ye s
Replace Digital Main CBA Unit.
When touching each buttons do the voltage of Pin(6)
of CN4001 decrease?
The key operation is not functioning.
FLOW CHART NO.1
Ye s Ye s
Replace Digital Main CBA Unit. Replace IC4001
or Function CBA.
No
Check AL+3.3V line and
service it if defective.
Is approximately +3.3V voltage supplied to Pin(1)
of CN4001?
No
No operation is possible from the remote control unit. (Operation is possible from the unit.)
Picture does not appear normally.
FLOW CHART NO.3
Is approximately +24V voltage supplied to Pin(13, 14)
of CN631?
Is
approximately +
3.3V voltage sup
plied to Pin(11) of
CN631?
Digital Main CBA Unit or LCD Panel Asse
mbly may
be defective.
Check and replace these parts.
No
No
Ye s
Is approximately +21V voltage supplied to
Pin(16, 17, 22, 23) of CN631?
See FLOW CHART NO.5 <P-ON+21V is not output.
[Power Supply Section]>
See FLOW CHART NO.7 <AL+3.3V is not output.
[Power Supply Section]>
See FLOW CHART NO.6 <AMP+24V is not output.
[Power Supply Section]>
No
Ye s
Ye s