Service Modes, Error Codes, and Fault Finding
EN 28 LC7.2E LA5.
Figure 5-18 Power Down & DC_PROT flowchart
Start
WriteProtect for NVM
Mute Audio & VIdeo
Power Down INT:
AC OFF or Transient INT
DC_PROT INT
STANDBYn = LOW
Wait 5000 ms
Re-start: Start up
End
No
Notes:
1. Power Down INT will be based on fall edge triggering
2. +3V3STBY will stay for 15ms, software must perform
WriteProtect for NVM within 15ms.
Poll the Power Down
INT for 5 times
End
Avoid false trigger
Start
Mute Audio & VIdeo
No
End
Avoid false trigger
is DC_PROT = LOW
for 3 sec?
Log Error Code
STANDBYn = LOW
WriteProtect for NVM
Error 1
[Protection]
End
Yes
Yes
G_16860_072.eps
220207