Philips Semiconductors
TDA9964
12-bit, 3.0 V, 30 Msps analog-to-digital interface for CCD cameras
Objective specification Rev. 03 — 16 January 2001 6 of 23
9397 750 07918
© Philips Electronics N.V. 2001. All rights reserved.
8. Limiting values
[1] The supply voltages V
CCA
, V
CCD
and V
CCO
may have any value between 0.3 and +7.0 V provided that the supply voltage difference
V
CC
remains as indicated.
9. Thermal characteristics
10. Characteristics
Table 4: Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol Parameter Conditions Min Max Unit
V
CCA
analog supply voltage
[1]
0.3 +7.0 V
V
CCD
digital supply voltage
[1]
0.3 +7.0 V
V
CCO
digital outputs supply voltage
[1]
0.3 +7.0 V
V
CC
supply voltage difference:
between V
CCA
and V
CCD
0.5 +0.5 V
between V
CCA
and V
CCO
0.5 +1.2 V
between V
CCD
and V
CCO
0.5 +1.2 V
V
i
input voltage referenced to AGND 0.3 +7.0 V
I
o
data output current −±10 mA
T
stg
storage temperature 55 +150 °C
T
amb
ambient temperature 20 +75 °C
T
j
junction temperature 150 °C
Table 5: Thermal characteristics
Symbol Parameter Conditions Value Unit
R
th(j-a)
thermal resistance from junction to ambient in free air 76 K/W
Table 6: Characteristics
V
CCA
=V
CCD
= 3.0 V; V
CCO
= 2.7 V; f
pix
= 30 MHz; T
amb
=25
°
C; unless otherwise specified.
Symbol Parameter Conditions Min Typ Max Unit
Supplies
V
CCA
analog supply voltage 2.7 3.0 3.6 V
V
CCD
digital supply voltage 2.7 3.0 3.6 V
V
CCO
digital outputs supply voltage 2.5 2.7 3.6 V
I
CCA
analog supply current all clamps active 60 mA
I
CCD
digital supply current 3 mA
I
CCO
digital outputs supply current C
L
= 10 pF on all data
outputs; input ramp
response time is 800 µs
1 mA