2PHILIPS AA5 (AA) Chassis
Teletext Diagram / Electrical Adjustments / Safety Parts / Repair Facilities / Repair Facilities Cont’d / CRT PCB (20” narrow neck)
Power Supply Diagram / Control Diagram / Video Audio CRT 14/15/17/21” mini neck Diagram / Teletext Diagram / Tuner IF Diagram
Repair facilities Cont’d
Service default mode (SDM)
The service default mode is a pre-defined mode
which can be used when for faultfinding
(especially when the TV gives no picture at all).
All oscillograms and DC voltages in this service
manual are measured in the service default
mode.
Entering the service default mode can be done
in 2 ways:
1. By short-circuiting the service pins Si and S2
of the microcomputer (pin 7 of 107600) while
switching on the set with the mains switch
2. From normal operation mode by pressing the
button “DEFAULT” on the DST (Dealer
Service Tool) RC7150.
Leaving the service default mode to normal
operation can only be done by the stand-by on
the remote control (so not via mains switch “off”;
after mains switch “off” and then “on” again the
set will start up in the Service Default Mode
again to enable easy faultfinding).
Functions of the service default mode
(see Fig 8.1):
1. All analog settings (volume, contrast,
brightness and saturation) are in the mid
position (in iC with Vi .0 the volume in the
SDM is set at 25%, from Vi .1 onwards the
volume in the SDM is set at 50%).
2. For VST sets are to program number 1
indicated in the right top corner
3. For PLL sets are tuned to 475.25 MHz
4. Delta volume settings are not used (delta
volume setting per program in reference with
the PP volume setting which is valid for all
programs)
5. OSD error message (present available error
code) is displayed continuously
6. Store open and store close commands will act
as search and auto store
7. Automatic switch off function (set switches
“off” after 15 minutes no DENT) will be
switched off
8. Hotel mode will be disabled
9. All other functions remain normal controllable
10.A counter in the middle of the screen indicate
the normal operation hours of the set in a
hexadecimal code (every time the set is
switched “on” the counter is incremented by 1
hour, so +i at the counter).
11. An “S” in the middle of the screen (next to
the counter) indicate that the set is in the
service default mode
Counter + “5” for SDM 0023 S 1
active + prog nr.
Fig. 8.1
Service Menu (SM)
Entering the service menu can be done in 2
ways:
1. From service default mode by simultaneously
pressing the buttons “-” and “+” buttons on the
local keyboard.
2. From normal operation mode by pressing the
button “ALIGN” on the DST RC7150.
Leaving the service menu to normal operation
can be done in 2 ways:
1. Via the stand-by on the remote control
2. Via mains switch “off”
For reading a new option setting, the set must
be switched “on” by the mains switch (so not by
stand-by as by then the EEPROM settings are
not read).
Functions of the service menu (see Fig 8.2);
1. Software version of the microprocessor used
in that typical set is displayed in the right top
corner
2. A counter in the middle of the screen indicate
the normal operation hours of the set in a
hexadecimal code (every time the set is
switched “on” the counter is incremented by i
hour, so+1 at the counter).
3. The “S” in the middle of the screen next to the
counter indicate that the set is in the service
default mode
4. Error code history; The 5 last different error
codes occurred are stored in the EEPROM
memory; last error code detected will be
displayed on the right side (see for an
overview of all possible error codes Fig. 8.4),
50 e.g.:
0 0 0 0 0
means no error codes present in the buffer
0 0 0 0 3
means one error code present in the buffer;
error code 3
0 0 0 3 2
means two error codes present in the buffer;
last detected error code is error code 2,
previous detected error code is error code 3
The error code history buffer is cleared as soon
as the Service Menu is left by the stand-by
command. In case the Service Menu is left by
the mains switch “off” the error code history
buffer will not be cleared.
Counter + “S” for SM 0023 S 1.0
active + software version
Error code history 0 0 0 3 2
Option setting bar - SYSTEM BG+l +
YNNYYNNNYYYN
Fig. 8.2
5. Option setting;
The options of the set can be changed in the
service menu. In the 2 bottom lines the options
are given. Control of the options is with the
following keys on the remote control:
* PROGRAM +/ -
Select the option to be changed;
Via the “PROGRAM +/-“ button to option to be
changed can be selected by scrolling through
the possible options in the upper row from left to
right (via the “PROGRAM +“ button) or from
right to left (via the “PROGRAM -“ button). The
selected option will be displayed in the upper
row, the present “Y” or “N” status of that option
(see table 8.3) will be blinking in the bottom row
(when arrived at the end of the row the scrolling
will be continued at the other side).
* MENU +/-
Change the selected option via “MENU +/-“
buttons the selected option can be changed.
The selected Y (yes) or N (no) blinks and via
either “MENU +“ or the “MENU you toggle
through the “Y” or “N” possibility.
The options (both the changed and the not-
changed options) are stored in the EEPROM as
soon as the service menu is left (by stand-by or
mains switch “off”). The new option settings are
only read after mains switch “on” (so not after
switching on the set from stand-by mode).
The following table indicates the possible
options and there technical consequences:
Error messages
The microcomputer also detects errors in
circuits connected to the I ~ (Inter IC) bus.
These error messages are communicated via
OSD (On Screen Display) and a flashing LED
both in normal operation and in the service
menu (error code history buffer):
1. In normal operation;
In normal operation both the “OSD error
message” and the “LED error” indication will
display the present detected error. The display-
ing of both the OSD and the LED error indica-
tion will only take a limited time.
2. In the service default mode;
In the service default mode both the “OSD error
message” and the “LED error” indication will
display the present detected error. In the service
default mode both the OSD and the LED error
indication will be displayed permanently.
3. In the service menu;
In the service menu both the “OSD error
number” (in the error code history) and the “LED
error” indication will display the present detected
error. In the service default mode both the OSD
and the LED error indication will be displayed
continuously.
→
→
→
→
Reset volume/program (delta volume) for all
programs at once
It is also possible to leave the service menu with
the MENU button. After one time pressing the
MENU button in the service menu, a new menu
is entered (see Fig. 8.5) in which the volume/
programs-settings (also called delta volume
settings) of nil. programs can be deleted. In
case YES is selected via the MENU+ button, all
volume/program-settings are deleted at once.
After another time pressing the MENU button
the TV will switch to normal operation (when the
service menu is entered via the pins Si and S2)
or service default mode (when the service menu
is entered with the DST).
Counter +“S” for SM 0023 S 1.0
active + software
version
Error code history 0 0 0 3 2
Reset all volume - RESET VOL/PROG +
NO YES
Fig. 8.5
Text displayed in In case the “N” or The technical consequence
the upper option row “Y” blinks, it can be for the selected option
in the service menu changed
SINGLE ➝ NN ➝ For a PAL BG only set
SYSTEM I ➝ NY ➝ For a PAL I only set
SYSTEM BG+L ➝ YN ➝ For a PAL BG + SECAM LL’ set
SYSTEM BG+L+l ➝ YY ➝ For a PAL BGI or PAL EGOKI + SECAM LL’ set
PLL TUNER N ➝ For a VST tuner set
Y ➝ For a PLL tuner set
NO TXT ➝ NN ➝ For a set without teletext
1P TXT ➝ NY ➝ For a set with 1 page WST teletext
4P TXT ➝ YN ➝ For a set with 4 page FLOF teletext
16/9 SWITCH N ➝ Disable 16/9 switching possibility
Y ➝ Enable 16/9 switching possibility
S-VIDEO N ➝ For a set without SVHS connectors
Y ➝ For a set with SVHS connectors
SCART N ➝ For a set without a scart connector
Y ➝ For a set with a scart connector
Note: The SCART option can only be
changed when the S-VIDEO option is “N”
SHARPNESS N ➝ Disable sharpness control
Y ➝ Enable sharpness control
LOCAL MENU N ➝ No ring menu after pressing
Y “MENU” on the local keyboard
➝ Ring menu after pressing “MENU” on the local keyboard
40 PROGRAMS N ➝ 70 programs can be stored
Y ➝ 40 programs can be stored
SLEEPTIMER N ➝ Disable sleeptimer function
Y ➝ Enable sleeptimer function
FOR GERMANY N ➝ Disable ATS function
ONLY Y ➝ Enable ATS function only works when ATS software is present)
Fig. 8.3
“OSD error “OSD “LED error” Error Possible
message” error “on/off” in SEC description defective
normal number” component
operation) (service menu)
No indication 0 No blinking LED No error —
ERROR: RAM 1 1 sec on / 1 sec kC error 1C7600
off
ERROR: BUS 2 2 sec on / 2 sec General 1
2
C1
2
C bus is
oft blocked
ERROR: 3 3 sec on / 3 sec EEPROM error 1C7655
EEPROM oft
ERROR: 4 4 sec on
I
4 sec Teletext error 1C770017702 or
TELETEXT oft option wrong
ERROR: 5 5 sec on / 5 sec PLL tuner error PLL tuner or
TUNER oft option wrong
Fig. 8.4
Hotel mode
* Hotel mode “on”
The hotel is activated when pressing simulta-
neously the “MENU” button on the local
keyboard and the “SLEEPTIMER or OSD”
button on the remote control while program 38
is selected for at least 3 seconds.
When the hotel mode is activated, this is
indicated by a “H+” on the OSD (this will be
displayed until the set is switched of by the
mains switch or via stand-by).
* Hotel mode “off”
Repeat above mentioned procedure once
again. When the hotel mode is de-activated,
this is indicated by a “H-” on the OSD (this will
be displayed until the set is switched of by the
mains switch or via stand-by).
* Functions of the hotel mode
- The volume present on the moment the hotel
mode was switched “on” is the maximum
volume level in the hotel mode.
- The install mode can not be opened (the
message “LOCKED” will be displayed for 3
seconds if a store open command is given).
- The delta volume menu can not be entered.
- PP (personal preference) can not be stored
(the message “LOCKED” will be displayed for
3 seconds if a PP-store command is given).
- At switch “on” (by mains switch or remote
control) program number 1 will always be
selected.